</table>
=== A Note on Using Active Devices ===
When your physical structure contains an active device, EM.Tempo performs an EM-circuit co-simulation that involves both the full-wave FDTD EM solver and the SPICE circuit solver. In a global self-consistent co-simulation, at each time step of the FDTD time marching loop, the electric and magnetic fields at the location of the device ports are used to compute the port voltages and currents. These quantities are then used in the SPCIE circuit solver to update all the voltages and currents at the internal nodes of the active device. The updated port voltages and currents are finally used to update the electric and magnetic fields in the physical mesh cells and the time marching loop proceeds to the next time step. 
----
 
{{Note|You can use active one-ports to define custom voltage or current sources for your entire physical structure rather than using one of the physical excitation source types of the navigation tree.}}
<table>